USAfixTM - Repair Guide (RG) - Master Email RG
- Test the Key Switch
 Level of Difficulty - Medium  Estimated Completion Time - 10 minutes
TASKI - SWINGO 450B

Tools Required
Tool 
Screwdriver-phillips

Parts Required


Step Procedure & Parts & Tools
1 DISCONNECT THE CHARGER PLUG ON THE BACK OF THE MACHINE TO DISCONNECT THE BATTERIES. REMOVE THE 6 SCREWS FROM THE CONTROL PANEL.
Screwdriver-phillips

2 PULL THE CONTROL PANEL/BACK OF HANDLE FROM THE MACHINE.

3 LOCATE THE KEYSWITCH ON HANDLE COVER.

4 PLACE A PAPER CLIP ON THE MAGNET TO MAKE SURE MAGNET IS STILL IN POSITION. IF KEYSWITCH IS OKAY, REASSEMBLE THE CONTROL PANEL AND RECONNECT THE BATTERIES.